Ultra 700VA UPS vs Ultra 850VA UPS - Ultra UPS Specifications

Article Index
Ultra 700VA UPS vs Ultra 850VA UPS
Ultra UPS Specifications
Ultra UPS Software and Battery Replacement
Ultra UPS Testing and Conclusion

Ultra 700VA and 800VA UPS Specifications:

All specifications where taken directly from Ultra's website.

 

Ultra 700VA 350 Watts Backup UPS:

 

General Backup Time 9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes (a PC with 15” LCD monitor)
Net Weight Kg (lbs) 2.58(5.67)
Digital Display No
Output Watts 350
UPS Capacity 700VA
Total Capacity
(Protection)
1200VA
No. of Sockets Style A UPSx3, Bypassx3
Voltage (Battery) Simulated sine wave at 120V +/- 5%
Frequency (Battery) 50 or 60Hz +/- 0.3Hz
Transfer Time 2-4 milliseconds, including detection time
Input Voltage (Single Phase) 120V +15%/-20% at line input
Frequency 50 or 60Hz +/- 10% (auto sensing)
Protection Unit Input Circuit breaker for overload & short circuit protection
Overload Protection AC Mode: If load exceeds 110% of nominal,
Buzzer beeps continuously. If load exceeds
120% of nominal for 30 seconds, 130% for 3
seconds, UPS shuts down automatically.
Back up Mode: If load exceeds 105% of
nominal for 20 seconds, 120% for 10 seconds,
130% for 3 seconds, UPS shuts down
automatically.
Short Circuit UPS output shuts off immediately
Surge Protection 1140 Joules, 2ms
Battery Type Sealed, maintenance-free lead acid battery, with 3-6 years typical lifetime
Typical Recharge Time 6 hours (to 90% of full capacity)
Protection Automatic self-test, Over discharge
protection, short circuit protection by fuse
Interface USB Battery low detecting, UPS on/off scheduling AC input/output power status display.
Alarm Battery Backup Slow beeping sound every 4 seconds
Battery Low Rapid beeping sound every second
Abnormal Charge AC Mode: Rapid beeping sound every 0.5 second
Overload Continuous beeping sound
Environment Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40?
Audible Noise <40dBA (1 meter from surface)

 

 

Ultra 850 VA 425 Watts UPS:

 

General Backup Time 16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes (a PC with 15” LCD monitor)
Net Weight Kg (lbs) 4.1(9.1)
Digital Display No
Output Watts 425
UPS Capacity 850VA
Total Capacity
(Protection)
1200VA
No. of Sockets Style A UPSx4, Bypassx4
Voltage (Battery) Simulated sine wave at 120V +/- 5%
Frequency (Battery) 50 or 60Hz +/- 0.3Hz
Transfer Time 2-4 milliseconds, including detection time
Input Voltage (Single Phase) 120V +15%/-20% at line input
Frequency 50 or 60Hz +/- 10% (auto sensing)
Protection Unit Input Circuit breaker for overload & short circuit protection
Overload Protection AC Mode: If load exceeds 110% of nominal,
Buzzer beeps continuously. If load exceeds
120% of nominal for 30 seconds, 130% for 3
seconds, UPS shuts down automatically.
Backup Mode: If load exceeds 105% of
nominal for 20 seconds, 120% for 10 seconds,
130% for 3 seconds. UPS shuts down
automatically.
Short Circuit UPS output shuts off immediately
Surge Protection 1520 Joules, 2ms
Battery Type Sealed, maintenance-free lead acid battery, with 3-6 years typical lifetime
Typical Recharge Time 6 hours (to 90% of full capacity)
Protection Automatic self-test, Over discharge
protection, short circuit protection by fuse
Interface USB Battery low detecting, UPS on/off scheduling AC input/output power status display.
Alarm Battery Backup Slow beeping sound every 4 seconds
Battery Low Rapid beeping sound every second
Abnormal Charge AC Mode: Rapid beeping sound every 0.5 second
Overload Continuous beeping sound
Environment Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-condensing, 0-40?
Audible Noise <40dBA (1 meter from surface)